High Vacuum and Central Cleaning
High negative pressure at low volume, with cyclone pre-separation and bag or cartridge secondary filtration. From pharma, food and biotech to PV, semiconductor and cleanrooms — scattered vacuum points gathered into one central system.

Central High-Vacuum Cleaning System
Power unit, controls, piping, valves and operating set
Five parts make the system: power unit, control, piping, valves and operating components. High vacuum at low flow is exactly what material recovery and cleanroom cleaning need. Small units use a side-channel blower, heavy dust loads switch to multistage centrifugal fans, and a cyclone plus bag or cartridge stage secures the discharge.
- High vacuum at low flow, suited to long pipe runs
- Two stages: cyclone then bag or cartridge
- Side-channel (Siemens-type) blowers on small units
- Multistage centrifugal fans for heavy dust loads
- Intake points placed as needed; product can be recovered
| Power unit | Side-channel blower or multistage centrifugal fan |
|---|---|
| Control | Central control cabinet |
| Piping | High-vacuum pipe network |
| Valves | Per-point changeover valves |
| Operating set | Quick couplings and wand |
| Filtration | Cyclone plus bag or cartridge |

High Vacuum Dust Collector
99.9% at 0.1 μm
High-vacuum collection of welding, cutting and grinding fume. Pleated cartridges give 300% more filtering area than bags in the same volume; pulse valves run at 0.2–0.6 MPa with a million-cycle life, and venturi cleaning works online.
- 99.9% efficiency on 0.1 μm fume
- Pleated cartridges: 300% more area than bags in the same volume
- Pulse valves at 0.2–0.6 MPa, million-cycle life
- Venturi cleaning, online operation
- For dry, oil-free, non-corrosive fume
| Fineness | 0.1 μm |
|---|---|
| Efficiency | 99.9% |
| Media | Pleated cartridges, 300% more area than bags |
| Pulse pressure | 0.2–0.6 MPa |
| Valve life | One million cycles |
| Cleaning | Venturi, online |
| Air quality | Dry air; non-corrosive, oil-free fume duty |